Radiation Measurements
Radiation Measurements can be made in two different but
related, system: the traditional (Britist) system, still commonly used in the
United states, and the Systeme Internationale (SI) units established by the
International Commission on Radiation Units in 1981. These units and their
relationships are summarized in below.
The traditional unit of radiation exposure is the roentgen (R),
a measurement of radiation intensity in air. The roentgen is equal to the
quantity of radiation that will produce 2.08 x 109 (more than 2
billion) ion pairs in 1 cm3 of dry air. The SI unit for measuring
radiation intensity is coulombs per kilogram (C/kg), specifying the quantity of
electrical charge in coulombs produced by the exposure of 1 kg of dry air. Once
roentgen equals 2.58 x 10-4 (.000258) C/kg.
The roentgen is useful for measuring the quantity of
radiation present but is not a useful dose measument. Dose varies with the
depth of measurement and the quantity of radiation energy absorbed in the
exposed tissue. The measure therapeutic radiation doses as well as specific
tissue doses received in diagnostic applications, the traditional unit is the
rad. Rad stands for radiation absorbed dose and equal to 100 ergs (an energy
unit) per gram of tissue. One roentgen of exposure will result in approximately
1 rad of absorbed dose in muscle tissue. The SI unit for dose measurement is
the Gray (Gy). One Grey equals 100 rad, and conversely, 1 rad equals to 1
centigray.
Biologic Effect of Radiation
The biologic effect of radiation exposure varies according
to the type of radiation involved and its energy. Equal doses of various types
of radiation, as measured in rad or Gy, will not necessarily result in equal
biologic effects. Some radiation workers, such as engineers in nuclear power
plants, nuclear submarine construction workers, or technologist in nuclear
medicine laboratories may be exposed to several types of radiation with unequal
level of biologic effect. Neither the roentgen not the rad is a useful unit for
measuring the occupational dose of combined radiations with different levels of
effects.
To simplify the process of measuring occupational dose, a
weighting factor (WF) number is assigned to each type of radiation based upon
its absorbed energy in a mass of tissue and its relative biologic effect as
compared to xrays. Formerly, weighting factors were called quality factors. The
weighting factors for different types of ionizing radiation are listed below.
For example, note that alpha particles have a WF of 20. This
is because 1 rad of alpha particles causes biologic effects that are
approximately equal to those produced by 20 rad of xray energy. The absorbed
dose is multiplied by the WF to obtain the dose equivalent. The resulting unit
is called the rem, which stands for roentgen equivalent in man. Thus, the
worker exposed to 1 rad of alpha particles would receive 20 rem of occupational
exposure.
Because the radiation quantities involved in diagnostic
radiology are so small, radiographers commonly use units that are 1 / 1000 of the
common unit (example, milliroentgens [mR], millirad [mrad], and millirem
[mrem]). For example, a chest radiograph may result in a skin entrance dose of
15 mrad, or 0.015 rad.
Students often find it confusing to determine which
radiation units should be used in a given situation. This is made more
difficult by the tendency of many radiographers to use the traditional
roentgen, rad, and rem units interchangeable. This does not cause serious
inaccuracy when speaking only of diagnostic xray, because exposure to 1
roentgen of xray energy will result in approximately 1 rad of absorbed dose on
muscle. Because the WF of diagnostic xray equals one, 1 rad is also equal to 1
rem.
In general, the reason for the measument determines which
unit is most appropriate. The R and C/kg units are used to measure the presence
of x-radiation without any reference to its absorption or attenuation (that is,
the quantity of radiation present in air). The rad and the Gy are used to
measure radiation dose. These units are used to prescribe radiation therapy. The
amount absorbed by a specific tissue is what is being measured, so a statement
indicating the part of the body involved usually modifies the rad dosage. For example,
a radiation oncologist may prescribe a treatment involving 150 centigray to the
liver, or a research report might state that the average patient who has a
routine chest radiograph receives a thyroid dose of 4 mrad. The laboratory that
processes personal radiation monitor badges will report occupational dose in
dose equivalent units: rem, mrem, or mSv.